KG24ZCD12C-500A CAN
本产品是采用磁通门技术,用于检测直流电流的数字传感器.
测量方式为穿孔式,无插入损耗,孔径为φ24mm.
This product is a digital sensor using fluxgate technology for detecting DC current.
The measurement method is perforated, no insertion loss, and the aperture is φ24mm.
|
产品特点Product characteristics |
应用Apply |
|
12V单电源供电 12V single power supply |
l 电池管理系统(SOC,SOH,SOF 等)的电流测量 Current measurement for battery management systems (SOC,SOH,SOF, etc.) |
|
额定电流测量范围±500A ±500A/Rated current measurement range ±500A |
|
|
工作温度范围:-40℃∽+85℃ Working temperature range: -40 ° C ∽+85 ° C |
|
|
输出信号:高速 CAN(500kbps)Output signal: High speed CAN(500kbps) |
|
|
在工作温度范围内0.5%的综合误差A combined error of 0.5% over the temperature range |
|
|
在常温25℃下0.3%的综合误差/The combined error of 0.3% at room temperature 25℃ |
|
|
原副边隔离测量Primary secondary side isolation measurement |
|
|
连接器类型:TE/AMP 1473672-1Connector type: TE/AMP 1473672-1 |
|
绝对最大额定值Absolute maximum ratings |
||||
|
参数 parameter |
符号 symbol |
单位 unit |
值 value |
测试条件 Test condition |
|
冲击电压 Impulse voltage |
Vc |
V |
32 |
400ms |
|
过电压 Over voltage |
Vc |
V |
24 |
1min |
|
负向耐压 Negative pressure resistance |
Vc |
V |
-16 |
1min |
|
最大供电电压 Maximum supply voltage |
Vc max |
V |
18 |
连续,不工作 Continuous, not working |
|
最小供电电压 Minimum supply voltage |
Vc min |
V |
6 |
连续,不工作 Continuous, not working |
|
爬电距离 Creepage distance |
dcp |
mm |
7.2 |
|
|
电气间隙 Electrical clearance |
dci |
mm |
6.95 |
|
|
绝缘电压 Insulation voltage |
Vd |
kV |
2.5 |
@50HZ,AC,RMS,2mA,1min |
环境和机械特性Environmental and mechanical characteristics
|
参数 parameter |
标志 symbol |
单位 unit |
最小值 Minimum value |
典型值 Typical value |
最大值 Maximum value |
备注 remark |
|
工作温度 Operating temperature |
TA |
℃ |
-40 |
85 |
||
|
存储温度 Storage temperature |
TS |
℃ |
-40 |
105 |
||
|
质量 Weight |
m |
g |
80 |
|||
|
IP 等级 IP level |
IP41 |
|||||
|
电气参数 Electrical data(Ta=25℃±5℃) |
||||||
|
参数 parameter |
标志 symbol |
单位 unit |
最小值 Minimum value |
典型值 Typical value |
最大值 Maximum value |
测试条件 Test condition |
|
额定输入电流 Rated input current |
Ipn |
A |
-500 |
- |
500 |
- |
|
测量电流范围 Measuring current range |
Ipm |
A |
-530 |
- |
530 |
- |
|
供电电源电压 Supply voltage |
Vc |
V |
8 |
12 |
16 |
- |
|
工作电压钳位 Working voltage clamp |
Vc |
V |
18 |
电压增加时,停止工作点 When the voltage increases, stop the operating point |
||
|
Vc |
V |
17.35 |
电压降低时,恢复工作点 Restore the operating point when the voltage drops |
|||
|
Vc |
V |
7.75 |
电压增加时,恢复工作点 When the voltage increases, stop the operating point |
|||
|
Vc |
V |
7.55 |
电压降低时,停止工作点 Restore the operating point when the voltage drops |
|||
|
电源消耗电流 Power supply consumption current |
Ic |
mA |
- |
35 |
50 |
@25℃,Vc=12V,IP=0A |
|
电源消耗电流 Power supply consumption current |
Ic |
mA |
- |
135 |
160 |
@25℃,Vc=12V,IP=500A |
|
线性度误差 Linearity error |
ε |
%FS |
-0.1 |
- |
0.1 |
@25℃ |
|
噪声电流 Noise current |
Ioe |
mA |
-10 |
10 |
@Ip=0,TA=25℃ |
|
|
温漂 Temperature drift |
TC |
ppm/℃ |
70 |
TA=-40~+85℃ |
||
|
综合误差 Combined error |
温度 temperature |
|
|
Ip(A) |
@25 |
@-40~85℃ |
|
0 |
±0.01 |
±0.01 |
|
10 |
±0.05 |
±0.07 |
|
100 |
±0.3 |
±0.5 |
|
200 |
±0.6 |
±1 |
|
300 |
±0.9 |
±1.5 |
|
400 |
±1.2 |
±2 |
|
500 |
±1.5 |
±2.5 |

CAN 输出规格 CAN output specification
CAN 接口特征:
CAN interface features:
CAN 协议:2.0B 版本/CAN protocol: version 2.0B
字节顺序/Byte order:大端序(Motorola)
CAN 振荡器容差:0.27%/CAN oscillator tolerance: 0.27%
无休眠能力/indormancy
外部添加 120 欧姆终端电阻,内部 CAN 阻抗=2.4kohm/Add 120 ohm terminal resistance externally and CAN impedance =2.4kohm internally
|
信息描述 Information description |
CAN 序号 CAN sequence number |
名称 name |
数据长度(Nb字节) Data length (Nb Bytes) |
框架 类型 Frame type |
信息启动类型 Message initiation type |
|
返回电流 IP(mA) Return current IP(mA) |
0x3C2 |
SG 500_IP |
8 |
标准 Standard |
循环收发消息 10ms 周期 The interval for sending and receiving messages is 10ms |
|
信号描述 Signal description |
信号名称 Signal name |
开始字节 Start byte |
长度 Length |
|
IP 值/IP value:80000000H=0mA 7FFFFFFFH=1mA 80000001H=1mA |
IP 值 IP value |
24 |
32 |
|
错误信息(1 字节)(0:正常,1:错误) Error message (1 byte)(0: normal, 1: error) |
错误提示 Error prompt |
32 |
1 |
|
故障错误(7 字节) Fault error (7 bytes) |
错误信息 Error message |
33 |
7 |
|
SG 500(24 字节) SG 500(24 bytes) |
传感器名字 Sensor name |
48 |
16 |
|
故障管理 Fault management |
|||
|
故障模式 Failure mode |
IP 值 IP value |
错误提示 Error prompt |
错误信息 Error message |
|
内存错误 Memory error |
0x FFFF FFFF |
1 |
0X40 |
|
过电流检测 IP>580A Overcurrent detection IP>580A |
0x FFFF FFFF |
1 |
0X41 |
|
磁通门在 20 毫秒以上没有振荡 The fluxgate does not oscillate for more than 20 milliseconds |
0x FFFF FFFF |
1 |
0X42 |
|
时钟偏差 Clock deviation |
0x FFFF FFFF |
1 |
0X44 |
|
电源电压超出范围 The power supply voltage is out of range |
0x FFFF FFFF |
1 |
0X46 |
|
硬件默认 ADC 通道 Hardware default ADC channel |
0x FFFF FFFF |
1 |
0X47 |
|
新数据不可用 New data is not available |
0x FFFF FFFF |
1 |
0X49 |
|
硬件默认 DAC 阈值 Default hardware DAC threshold |
0x FFFF FFFF |
1 |
0X4A |
|
硬件默认参考电压 Default hardware reference voltage |
0x FFFF FFFF |
1 |
0X4B |
|
结构参数 Dimensions(in mm)
|
|||
Hot Tags: kg24zcd12c-500a can, China kg24zcd12c-500a can manufacturers, suppliers, factory, Split Core Current Sensor SZ140KBD12, Weigh Bridge Indicator, OIML Approve Double ended Beam Load Cell, Plastic Indicator, Rocker Weighing Module, Truck Scale Digital Indicator
Previous
KG24ZCD24C-500A CANNext
FSP2005-70You Might Also Like