FSM200EIG
|
Electrical characteristics |
|||
|
Type |
FSM200EIG |
||
|
IPN |
Primary nominal input current |
200 |
A |
|
IP |
Measuring range of primary current primary current |
0~±300 |
A |
|
ISN |
Nominal output current |
200 |
mA |
|
KN |
Conversion ratio |
1:1000 |
- |
|
RM |
(TA=25℃) Measuring resistance |
VC=±12V IP=±200 0-12 |
Ω |
|
VC=±15V IP=±200 0-25 |
Ω |
||
|
VC |
Supply voltage |
±12~±15(±5%) |
V |
|
IC |
Current consumption |
VC=±15V 30+Is |
mA |
|
X |
Accuracy |
TA=25℃ ±0.01 |
% |
|
εL |
Linearity |
<0.005 |
% |
|
TT |
Time stability |
0.2 |
ppm/month |
|
TV |
Power supply interference |
1 |
ppm/V |
|
I0 |
Offset current |
TA =25℃ <±0.1 |
uA |
|
IOT |
Offset current temperature drift |
IP=0 TA=-25~+70℃ <±10 |
uA |
|
Tr |
Response time |
90%IPN <1 |
μs |
|
di/dt |
Follow accuracy |
>100 |
A/μs |
|
f |
(-3dB) Frequency bandwidth(-3dB) |
DC~300 |
kHz |
|
- |
Output Valid |
LED on + low level signal (Max 2mA) |
- |
|
Dimensions of drawing(mm)
Definition:
Indicator light and indication signal description: Under normal operating conditions, the effective indicator is steady on. If the indicator light is off, it indicates that the current sensor is in a non-zero flux state, such as the bus current exceeds the range. At this time, the sensor enters the scanning state, the output current is no longer proportional to the input current signal, once the bus current falls back to the range, the sensor will resume normal work. The effective indicator signal and the indicator light are driven by the same signal, which is the OD gate output form, and the output corresponds to a low level when it is effective. |
Hot Tags: fsm200eig, China fsm200eig manufacturers, suppliers, factory, Detection and Measurement Light Curtain, EV Current Sensor SP31MD12, Hall Effect Current Transducer SC135T, Plastic Indicator, Digital Canister Load Cell, File Warehouse Management